6
© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO167/207/237
SCANNER
6 - 19
[C] Automatic original detection sensor (APS sensor)
[C-1] A4 series (S9-S13)
[C-2] LT series (S10-S13)
(1) Take off the original glass.
P.6-17 "[A] Original glass"
(2) Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 5 APS sen-
sors.
Note:
When installing the automatic original detec-
tion sensor, connect the connector (yellow)
to the connect one.
Fig. 6-17
(1) Take off the original glass.
P.6-17 "[A] Original glass"
(2) Disconnect 1 connector and remove 1 screw
for each APS sensor. Take off 4 APS sen-
sors.
Note:
When installing the automatic original detec-
tion sensor, connect the connector (yellow)
to the connect one.
Fig. 6-18
Sensor
Connector (Yellow)
Connector
Sensor
Connector
Connector (Yellow)