14
© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO167/207/237
AUTOMATIC DUPLEXING UNIT (ADU) (OPTION: MD-0103)
14 - 11
14.6 Flow Chart
Fig. 14-7
ADU motor ON
Exit motor reverse rotation ON
Specified time has passed
Specified time has passed
Specified time has passed
NO
YES
ADU sensor ON?
ADU transport jam (E51)
ADU motor stopped
ADU misfeeding (E11)
NO
YES
NO
YES
Registration sensor
ON?
Registration in process
Registration process completed
ADU motor stopped
Next paper is ready for the
registration
ADU paper feeding
command signal
received
ADU motor ON
ADU feeding operation started

Table of Contents