1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC © 2018 TOSHIBA TEC CORPORATION All rights reserved
1-20
To Have Uniform Variations in the Image Quality after Return from the Auto Power Save
Mode:
Change the value of the 08-2507 to change the conditions for starting image quality control (shorten
the period of time the MFP is left unused) after the MFP was recovered from the auto power save
mode, so that the image quality control will be easily performed.
Image quality control is performed before the start of a job.
For a more stable image quality on Low/Middle density, switch the image quality control to start to
the Full Mode with code 08-2492. (0: Disabled, 1: Short, 2: Full)
<Note>
• Do not disable the Auto shut off mode timer setting (“0” is set for 08-9112) while the Auto power
save timer setting is set to invalid (“0” is set for 08-9111). If both settings are set to invalid, this
equipment does not enter the energy saving mode so it is always in the ready status. Due to this,
image quality control according to the period of time the MFP is left unused is not performed
regardless of the setting value of 08-2507.
• After setting the value for code 08-2507, forcibly perform image quality control, as follows:
Select [05 ADJUSTMENT MODE], select code [2742], and then press the [START] button.
Value for
08-2507
Period of time the MFP is left unused before starting image quality control
0 3 minutes or longer
1 5 minutes or longer
2 7 minutes or longer
3 10 minutes or longer
4 15 minutes or longer
5 20 minutes or longer
6 30 minutes or longer
7 45 minutes or longer
8 60 minutes or longer
9 90 minutes or longer
10 120 minutes or longer
11 150 minutes or longer
12 180 minutes or longer
13 240 minutes or longer
14 300 minutes or longer
15 360 minutes or longer (default value)