e-STUDIO205L/255/305/355/455 © 2009 TOSHIBA TEC CORPORATION All rights reserved
ADJUSTMENT
3 - 2
3.2 Adjustment of Auto-Toner Sensor
When the developer material is replaced, adjust the auto-toner sensor in the following procedure.
<Procedure> (Adjustment Mode (05-200))
(1) Install the process unit into the equipment.
(2) While pressing [0] and [5] simultaneously, turn the power ON.
The following message will be displayed.
Fig. 3-2
(3) Key in code [200] and press the [START] button.
The display changes as follows.
Fig. 3-3
Notes:
• A indicates the controlled value of the auto-toner sensor output. Press the Up or Down button
to change the value.
• B indicates the output voltage of the auto-toner sensor (2.30 V in the above case).
The drum, developer unit, etc. are in operation.
• C indicates the latest adjustment value.
(4) After about two minutes, the value B automatically starts changing.
Fig. 3-4
[0][5]
[POWER]
100%
TEST MODE
A3
A
[200] [START]
230%
128
200
TEST MODE
A3
128
A
B
C
230%
128
200
TEST MODE WAIT
A3
128