FIRMWARE UPDATING
8 - 38
8.3.6 Finisher firmware (MJ-1101)
Important:
Be sure to shut down the equipment before installing and removing the download jig.
Do not shut down the equipment during the update. The data could be damaged and not be
operated properly.
[A] Update Procedure
(1) Install the ROM to the download jig (K-PWA-DLM-320).
Make sure the direction is correct.
(2) Press the [ON/OFF] button on the control panel to shut down the equipment and turn the power
OFF using the main power switch.
(3) Remove 1 screw and take off the board access cover.
Fig. 8-38
(4) Connect the download jig with the jig connector (CN9) on the Finisher control board.
Fig. 8-39
(5) Turn the power ON using the main power switch while simultaneously holding down the [0] and
[8] buttons.
Updating starts and the LED on the download jig lights