FIRMWARE UPDATING
8 - 37
(7) After the update is completed properly, the LED on the download jig blinks slowly (at interval of
0.8 sec). The LED starts blinking in approx. 30 sec. (finisher section) or 2 min. 30 sec. (saddle
stitcher section) since the update starts. It is assumed that the update is failed if it does not start
blinking even though 1 min. has passed (finisher section) or 3 min. (saddle stitcher section), or
LED flashes fast (at interval of 0.1 sec.). In this case, turn OFF the power and check the following
items. Then, clear the problem and restart updating from the beginning.
Is the download jig connected properly?
Is the ROM installed to the download jig properly?
Is the updating data written on the ROM of the download jig properly?
Do the download jig and the equipment operate properly?
Is the DIP switch on the finisher control PC board set properly according to the download
section (finisher or saddle stitcher)?
(8) Press the [ON/OFF] button on the control panel and turn the power OFF using the main power
switch and remove the download jig.Return the DIP switch to the status before updating.
(9) Install the finisher rear cover.
[B] Confirmation of the updated data
After the updating is completed, check each data version in Setting Mode (08) to confirm that the data
were overwritten properly.
P.8-50 "8.4 Confirmation of the updated data"
Processing status
LED
LED103 LED102 LED101
0% or above OFF OFF ON
15% or above OFF ON OFF
30% or above OFF ON ON
45% or above ON OFF OFF
60% or above ON OFF ON
75% or above ON ON OFF
90% or above ON ON ON