6
© 2009 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO205L/255/305/355/455
ERROR CODE AND TROUBLESHOOTING
6 - 125
6.4.6 Poor fusing
Fig. 6-6
Defective area Step Check items Prescription
Heater electric power 1 Check if the connector contacts
properly.
Correct it.
2 Is the heater shorted or broken? Replace the heater.
Pressure between fuser
roller and pressure roller
3 Are the pressure springs working
properly?
Check and adjust the pressure
springs.
Fuser roller temperature 4 Is the temperature of the fuser roller
normal?
Check the setting and correct it.
08-407, 410, 411, 450, 515, 516,
(
5285: e-STUDIO355/455)
Developer material/Toner 5 Using the specified developer
material and toner?
Use the specified developer material
and toner.
Paper 6 Is the paper in the drawer or LCF
damp?
Avoid storing paper in damp place.
7 Is the paper type corresponding to its
mode?
Use the proper type of paper or
select the proper mode.
8 Is the setting temperature of the fuser
roller in each paper type normal?
Check the setting and correct it.
08-412, 413, 437, 438, 451, 452,
453, 518, 520, 521
(5328, 5329, 5330, 5331, 5332: e-
STUDIO355/455)
9 Using the recommended paper? Use the recommended paper.
Feeding direction