EasyManua.ls Logo

Toshiba e-STUDIO557 - Page 108

Toshiba e-STUDIO557
754 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
© 2011 - 2014 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO556/656/756/856/557/657/757/857
ERROR CODE AND TROUBLESHOOTING
8 - 107
[F110] Communication error between System-CPU and Scanner-CPU (e-STUDIO557/657/757/
857)
[F111] Scanner response abnormality (e-STUDIO557/657/757/857)
Replace parts Remarks
SYS board
LGC board
HRNS-LGC-SYS-H100
Classification Error content
Communication related service call Communication error between System-CPU and Scanner-CPU Scanner
response abnormality
Check item Measures
Reproducibility Turn the power OFF and then back ON using the main power switch.
SYS Board Check if the conductor pattern on the SYS board is short circuited or
open circuited.
Connector check (CN131)
Harness check (CN131)
Replace parts Remarks
SYS board

Table of Contents

Other manuals for Toshiba e-STUDIO557