EasyManua.ls Logo

Toshiba e-STUDIO557 - Setting Mode (08) Codes; Process

Toshiba e-STUDIO557
754 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
e-STUDIO557/657/757/857
1
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
08
Setting
Mode
Process Fuser 2002 Fuser unit counter 0 0~29 M
0: No error 1: C411 2: C412 3: C443 4: - 5:
C445/465 6: C446/466 7: C447/467 8: C468 9: C449
10: C475 11: C471 12: C472 13: C473 14: C481 15:
C480 16: C474 17: C490 18: C468 19: C449 20:
C468 21: C449 22: C449 23: C449 24: C447/C467
25: C449 26: C468 27: C449 28: C468 29: C449
1
08
Setting
Mode
Process Fuser
Fuser roller
temperature at ready
status
2009 0 Normal temperature
Refer to
contents
0~14 M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
e-STUDIO557: 9
e-STUDIO657:
JPC: 9
Other: 12
e-STUDIO757/857: 12
4
08
Setting
Mode
Process Fuser
Fuser roller
temperature at ready
status
2009 1 Low temperature
Refer to
contents
0~14 M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
e-STUDIO557/757/857: 12
e-STUDIO657:
JPC: 9
Others: 12
4
08
Setting
Mode
Process Fuser
Fuser roller
temperature during
printing
Plain paper 2010 0 Normal temperature
Refer to
contents
0~14 M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
e-STUDIO557: 6
e-STUDIO657/757/857:12
4

Table of Contents

Other manuals for Toshiba e-STUDIO557

Related product manuals