e-STUDIO557/657/757/857
1
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
05
Adjustmen
t mode
Process Developer 2000
Automatic adjustment
of auto-toner sensor
- -
The adjustment starts approx. 3 minutes after this
mode has been selected, and then the value is
automatically adjusted. The adjustment value is fixed
by pressing the [ENTER] button.This selection is
disabled when the developer unit is not installed.
17 Yes
05
Adjustmen
t mode
Process Developer 2001
Correction of auto-
toner sensor
128 0-255 M
The adjustment value of the auto-toner sensor set in
the code 05-2000 is verified.This selection is disabled
when the developer unit is not installed.
3 Yes
05
Adjustmen
t mode
Process Developer 2020
Developer bias output
adjustment
(Developer bias ON)
113 0-255 M
The developer bias is output. Use this code to verify the
output value of the high-voltage transformer.The value
is output while the developer unit is taken off from the
drum.
3
05
Adjustmen
t mode
Process Charger 2040
Main charger grid bias
output adjustment
102 0-255 M
The main charger grid bias is output. Use this code to
verify the output value of the high-voltage
transformer.Take off the developer unit to enable this
code.
3
05
Adjustmen
t mode
Process Transfer 2052
Transfer transformer
DC output adjustment
(C)
138 0-255 M
When the value increases, the transfer transformer
output increases. The output value of the transfer belt
power supply roller is unmeasurable since its voltage is
extremely high.Make sure to close the front cover when
this code is used. Never touch the high-voltage
section.This selection is disabled when the developer
unit is not installed.
3
05
Adjustmen
t mode
Process
Image
quality
control
2120
Image quality control
enforcement
- M
Image quality control is performed forcibly when the
density correction of the image is required.
6 Yes
05
Adjustmen
t mode
Process
Image
quality
control
2133 Control status display 0 0-4 M
The control status of image quality control is displayed.
0: Normal
1: Error (control stopped)
2: Error (abnormal pattern density)
4: Sensor LED off-level abnormality or sensor LED light
amount abnormality
2 Yes
05
Adjustmen
t mode
Process
Image
quality
control
2134
Sensor output value
when LED light
source is OFF
0 0-1023 M
Displays a sensor output value when the light source of
the LED is OFF.
2