e-STUDIO557/657/757/857
2
05/08 Mode Element
Sub
element
Item Subitem Code
Sub-
code
Details
Default
value
Acceptable
value
RAM Contents
Proce
dure
Servic
e UI
05
Adjustmen
t mode
Process
Image
quality
control
2136
Low density pattern
sensor output value
0 0-1023 M
The value of the low density pattern detected at the
image quality closed-loop control is displayed.
2
05
Adjustmen
t mode
Process
Image
quality
control
2137
High density pattern
sensor output value
0 0-1023 M
The value of the high density pattern detected at the
image quality closed-loop control is displayed.
2
05
Adjustmen
t mode
Process
Image
quality
control
2138
Result display of
image quality sensor
light amount
adjustment
0 0-255 M
The result of the sensor LED light amount adjustment
(to use the reflection amount from the drum surface as
a reference) is displayed.
2
05
Adjustmen
t mode
Process
Image
quality
control
2160
Drum surface
potential sensor
control status
0 0-2 M
0: Normal,1: Error (control stopped),2: Error (sensor
abnormality)
2
05
Adjustmen
t mode
Process
Image
quality
control
2162
Drum surface
potential sensor
output (Latest
value)(Center
voltage)
0 0-999 M
The drum surface potential of the main charger center
bias measured by the sensor is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.
2
05
Adjustmen
t mode
Process
Image
quality
control
2165
Drum surface
potential sensor
output (Latest
value)(Low voltage)
0 0-999 M
The value of the main charger grid bias measured with
the drum surface potential sensor is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.
2
05
Adjustmen
t mode
Process
Image
quality
control
2166
Drum surface
potential sensor
output (Latest
value)(High voltage)
0 0-999 M
The value of the main charger grid bias measured with
the drum surface potential sensor is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.
2
05
Adjustmen
t mode
Process
Image
quality
control
2171
Drum surface
potential sensor/
Residual voltage
sensor output(Latest
value)
0 0-999 M
The measured value of the residual voltage after
discharging is displayed.
* The normal range of this code is "400 to 800" after
performing 05-2188.