e-STUDIO557/657/757/857
2
element
code
value
value
dure
e UI
Mode
temperature during
printing
Plain paper 2010 1 Low temperature
contents
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
<Default value>
e-STUDIO557: 8
e-STUDIO657/757/857:12
Mode
temperature during
printing
2028 Thick paper 3 12 0~14 M
0: 140°C 1: 145°C 2: 150°C 3: 155°C 4: 160°C 5:
165°C 6: 170°C 7: 175°C 8: 180°C 9: 185°C 10:
190°C 11: 195°C 12: 200°C 13: 205°C 14: 210°C
Mode
waiting
Temperature setting 2030 0 Thick paper 3
contents
Sets the temperature at which low-temperature
warming-up control starts.
0: 130℃ 1: 135℃ 2: 140℃ 3: 145℃ 4: 150℃ 5:
155℃ 6: 160℃ 7: 165℃ 8: 170℃ 9: 175℃ 10:
180℃ 11: 185℃ 12: Disabled
<Default value>
e-STUDIO557: 5
e-STUDIO657:
JPC: 5
TWD: 6
Others: 7
e-STUDIO757/857:
JPC: 7
Others: 9
* The setting value of this code is applied when “0”
(disable) is set to the code 08-2226-5.