162 H7 ASD Operation Manual
Acceleration Time Adjustment
Program
Terminal Selection Parameters
Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Acceleration Time. Selecting either VI/II or RR enables this
feature. The selected input is used as a multiplier of the programmed
Acceleration Time setting. The multiplication factor may be from 1 to 10.
Note: An acceleration time shorter than the load will allow may cause nuisance
tripping and mechanical stress to loads.
Settings:
Disabled
VI/II
RR
Direct Access Number F652
Parameter Type Selection List
Factory Default Disabled
Changeable During Run — Ye s
Deceleration Time Adjustment
Program
Terminal Selection Parameters
Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Deceleration Time. Selecting either VI/II or RR enables this
feature. The selected input is used as a modifier of the programmed
Deceleration Time setting.
Note: A deceleration time shorter than the load will allow may cause nuisance
tripping and mechanical stress to loads.
Settings:
Disabled
VI/II
RR
Direct Access Number F653
Parameter Type Selection List
Factory Default Disabled
Changeable During Run — Ye s
Torque Boost Adjustment
Program
Terminal Selection Parameters
Analog Input Functions
This parameter Enables/Disables the feature that allows for the external
adjustment of the Torque Boost setting. Selecting either VI/II or RR enables
this feature. The selected input is used as a modifier of the programmed Torque
Boost setting.
Settings:
Disabled
VI/II
RR
Direct Access Number F654
Parameter Type Selection List
Factory Default Disabled
Changeable During Run — Ye s