Check code Operation cause
[80]
Gas temp. sensor (Tha) short circuit Tha sensor open/short
Open/short of Tha sensor was detected. Check connector (Tha sensor: PJ1) and characteristics of sensor
resistance value.
When sensor is normal, replace interface PC board of the Multi Controller.
Check code Operation cause
[81]
Gas temp. sensor (Thb) short circuit Thb sensor open/short
Open/short of Thb sensor was detected. Check connector (Thb sensor: PJ2) and characteristics of sensor
resistance value.
When sensor is normal, replace interface PC board of the Multi Controller.
Check code Operation cause
[82]
Gas temp. sensor (Thc) short circuit Thc sensor open/short
Open/short of Thc sensor was detected. Check connector (Thc sensor: PJ3) and characteristics of sensor
resistance value.
When sensor is normal, replace interface PC board of the Multi Controller.
Check code Operation cause
[83]
Gas temp. sensor (Thd) short circuit Thd sensor open/short
Open/short of Thd sensor was detected. Check connector (Thd sensor: PJ4) and characteristics of sensor
resistance value.
When sensor is normal, replace interface PC board of the Multi Controller.
Check code Operation cause
[84]
Gas temp. sensor (Thx) short circuit Thx sensor open/short
Open/short of Thx sensor was detected. Check connector (Thx sensor: PJ5) and characteristics of sensor
resistance value.
When sensor is normal, replace interface PC board of the Multi Controller.
Troubleshooting
Diagnostic procedure for check code