Domestic Hot Water Heat Pump Service Manual
6
2.0 Specifications
Physical data
Domestic Hot Water Heat Pump
Dimensions (Height x Diameter)
Nominal insulation thickness
Refrigerant charge CO2 equivalent
Water connections (cold & hot water)
Water connections (entry angle)
Condensates water connections
Max water side operating pressure
Domestic Hot Water Heat Pump
COP at Air7°C W10°C-52,9°C (EN16147)
Heat up time (A7°C W10°C-53,5°C)
COP at Air20°C W10°C-52,9°C (EN16147)
Heat up time (A20°C W10°C-53,5°C)
Maximum Qty of water by electric heater
only
Maximum water temperature
Heat pump operating range (min/max)
Auxiliary Power input (Paux)
Standby Power input (Pes)
Sound power level - Air7°C W10°C-52,9°C
(EN16147)
Sound power level - Air20°C W10°C-52,9°C
(EN16147)
Airflow rate nominal (min - max)
Maximum external static pressure
Minimum room volume (non-ducted unit)
Fan Curve
The graph shows the external static pressure vs airflow
at different fan speeds.
In order to assure an efficient operation, it is suggested
to keep the external pressure drops below 200 Pa.