STATION WIRING, POWER IP5000-Series Telephone Tilt Angles
IPT Installation Manual Feb,, 2015 1-5
STATION WIRING, POWER The IP5000-series IPTs can be powered by a local power supply at each
station or a 802.3af compliant Power-Over-Ethernet (PoE) device.
Use IEEE CAT5E (minimum) IP cable with a connector boot length not
greater than 1.6 inches (40 mm). For gigabit ethernet operation CAT6
cable is recommended.
All IP5000-series telephones are packaged with a 9 ft., 10 in. (3 m) IP
cable.
CAUTION! When powering up by PoE you must leave the LAN cable
UNPLUGGED for a minimum of five seconds before
plugging it back into the IP5000-series IPT or PoE switch.
In some situations the IP5000 cannot start without this
short interval.
IP5000-series telephones equipped with an ADM may require a local
power supply if the PoE switch cannot provide sufficient power for both
the phone and the ADM. Refer to Table 1-3 on Page 1-8 of this chapter for
power requirements.
CAUTION! As above, when powering up by AC power adapter, you
must leave the adapter cable UNPLUGGED for a
minimum of five seconds before plugging it back into the
IP5000-series IPT. In some situations the IP5000 cannot
start without this short interval.
The IP5000-series handset connects with a two-pair modular handset
cable included with the telephone.
An ADM connects to the IP5000-series station only with the modular
cable included with the ADM.
Connector Boot Length
less than 1.6 in. (40 mm)