IP5000 SERIES TELEPHONE POWER RATINGS IP5000-Series Telephone Tilt Angles
1-8 IPT Installation Manual Feb,, 2015
IP5000 SERIES
TELEPHONE POWER
RATINGS
Power Consumption (IEEE802.3af 48Vdc) of IP5000-series stations and
add-on modules.
Table 1-3 IP5000 Series POE Power Ratings
Telephone
Model
1
Option
Power Rating
(Watts)
Current
(A)
2
Typical
Watts
3
Typical
Current (A)
4
IEEE802.3af
PD class
Model Qty
IP5x22-SD
IP5x22-SDC
IP5132-SD
IP5x31-SDL
none – – 7.4 0.15 6.2 0.13 0
IP5xx + IDM5060 3 10.3 0.21 8.6 .018 0
IP5xx + IDM5060 2 9.4 0.20 7.8 0.16 0
IP5xx + IDM5060 1 8.4 0.18 7.0 0.15 0
IP5xx + LM5110 2 10.3 0.21 8.6 0.18 0
IP5xx + LM5110 1 9.4 0.20 7.8 0.16 0
IP5xx + KM5020 2 8.9 0.19 7.4 0.15 0
IP5xx + KM5020 1 8.2 0.17 6.8 0.14 0
1. Power ratings are only telephone and option modules consumption. The values do not include LAN
cable power loss, and apply to PoE, not local power supplies.
2. Current (A) = Power Rating (watts) / 48 v
3. Typical means that it is only an example and there is no guarantee implied. The “typical” value might
be used for a calculation of actual UPS backup time in an average installation.
4. Typical Current (A) = Typical Watts / 48 v