CO Line Specifications IPT Initialization
IPT Installation Manual Feb,, 2015 1-19
Loop start only
REN (Ringer Equivalence Number) is one
DTMF dialing
No AROH (Automatic Release Of Hold)
Ring frequency: 15.3 Hz to 68 Hz
Ring voltage: Must be greater than 30 vrms
Ringing ON Time must be greater than 500 ms and less than six
seconds. If continuous ringing for more than six seconds occurs the
IP5122-SDC will stop ringing and the LED will stop flashing.
Note: Connection to a PBX is not supported.
Note: The total REN of the devices attached to the CO Line (i.e.;
Two IP5122-SDCs and one FAX = 3 REN) must not exceed
the specification from the PSTN CO.
IPT Initialization The IP5122-SDC has a fourth initialization option (FB04). ACO Default.
1. Place the telephone in Programming Mode - Press 3+6+9+Hold
simultaneously.
2. Press Vol s then press Hold.
3. Press FB04.
FB04 ON = Revert to factory default ACO settings
FB04 OFF = Use the saved ACO settings
Features And Feature
Interaction
The CO Line is accessed directly when the ACO key is selected, the
IP5122-SDC then acts as a single line DTMF telephone. No IPedge/
IPedge
PSTN
LAN
MDF
Protectors
One CO Line circuit can be bridged to a maximum
of four IP5122-SDC stations, provided the total REN
does not exceed the PSTN CO Line circuit REN.