– 91 –
<1-way Cassette (YH) Type, Floor Standing Type, Concealed Duct High Static Pressure Type,
Floor Standing Concealed Type, Floor Standing Cabinet Type, Fresh Air Intake Type>
DC5V
DC5V
CN2 CN1
DC5V
EEPROM
CPU
CPU
DC5V
DC12V
DC20V
X
Y
AB AB AB
LNU1
U1 U2
U2
HA
RS
U1 U2
R
S
U1 U2
EEPROM
Power
supply
circuit
Function setting
Key switch
Remote controller
communication circuit
Display
LCD
Display
LED
Rechargeable
battery
LCD
driver
Display
LCD
Function setting
Key switch
Power
supply
circuit
*3
Outdoor
unit
Outdoor
unit
Power
source
Power
source
#2 #3
Sameas left
*2
Sameas left
*2
Up to 8 units can
be connected. *1
Indoor/outdoor communication
Outdoor
unit
Power source
1Ø 220-240V, 50Hz
1Ø 220V, 60Hz
Central
control
remote
controller
(optional)
(In case of
A
I-NETWORK)
Switch setting
Power supply circuit
Remote controller
communication
circuit
AI-NET
communication
circuit
Transformer
CPU
H8/3687
Indoor control P.C. board (MCC-1403)
PMV
Louver
motor
Drain
pump
Indoor
fan
motor
*
Not applicable to concealed duct high static pressure type
Power supply circuit
Driver
Remote
controller
communication
circuit
TA sensor
TCI sensor
TC2 sensor
TCJ sensor
Float input
*
Not applicable to concealed
duct high static pressure type
CPU
H8/3039
In operation
Alarm
Getting ready
Thermostat ON
COOL
HEAT
FAN
AC
synchronization
signal input circuit
BUS
communication
circuit
External
output
Transformer
Fan motor
control circuit
Wireless remote controller kit
Remote controller
communication
circuit
Sensor
section
Display
section
* 1-way Type only
“1:1 model” connection interface (optional)
Indoor unit
#1
“1:1 model”
connection
interface P.C.
board
(MCC-1401)
Wired (Simple) header remote controller
(up to 2 units)
Schedule timer
*1 Only up to 7 units
if a “1:1 model”
connection interface
is installed.
*2 The “1:1 model”
connection interface
can only be installed
in one unit.
*3 A schedule timer
cannot be connected
to a simple remote
controller.

Table of Contents