P9 ASD Quick Start Guide 73
* Reset ignored if active.
*POFF Control Under-Voltage Under-voltage condition at the 5,
15, or the 24 VDC supply.
Defective Control board.
Excessive load on power supply.
Low input voltage.
PtSt Reference Point Two speed-reference frequency
setpoint values are too close to
each other.
Two speed reference frequency setpoints are too close to
each other (increase the difference).
UC Under-Current With the Low-Current Trip
(F610) parameter enabled, the
output current of the ASD is
below the level defined at F611
and remains there for a time
longer than the setting of F612.
Output current too low.
LED
Screen
LCD
Screen
Description Possible Causes/Troubleshooting