EasyManua.ls Logo

Toshiba RAS-10JAVP-E - Specifications of Electrical Parts

Toshiba RAS-10JAVP-E
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
5-2. Outdoor Unit
RAS-10JAVP-E, RAS-13JAVP-E
5. SPECIFICATIONS OF ELECTRICAL PARTS
5-1. Indoor Unit
RAS-10JKVP-E, RAS-13JKVP-E
No.
1
2
3
4
Parts name
Fan motor (for indoor)
Thermo. sensor (TA-sensor)
Heat exchanger temp. sensor
(TC-sensor)
Louver motor
Type
MF-280-30-1
( )
( )
MP24GA
Specifications
DC280340V, 30W
10k at 25°C
10k at 25°C
Output (Rated) 1W, 16poles, 1phase DC12V
No.
1
2
3
4
5
6
7
8
9
Parts name
Reactor
Outside fan motor
Suction temp. sensor
(TS sensor)
Discharge temp. sensor
(TD sensor)
Outside air temp. sensor
(TO sensor)
Heat exchanger temp. sensor
(TE sensor)
Terminal block (6P)
Compressor
Compressor thermo.
Model name
CH-57
ICF-140-43-1
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA91A1F-45F
US-622KXTMQO-SS
Rating
L=10mH, 16A x 2
DC140V, 43W
10k (25°C)
62k (20°C)
10k (25°C)
10k (25°C)
20A, AC250V
3-phases 4-poles 750W
OFF: 125 ± 4°C, ON: 90 ± 5° C

Other manuals for Toshiba RAS-10JAVP-E

Related product manuals