6-2. Operation Data
<Cooling>
<Heating>
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
(2) Connecting piping condition : 5 m
Temperature
condition (°C)
Indoor Outdoor
27/19 35/
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
12 to 14 41 to 43
10 to 12 43 to 45
Model
name
RAS-
10JKVP-E
13JKVP-E
Standard
pressure
P (MPa)
0.9 to 1.1
0.8 to 1.0
Indoor fan
mode
High
High
Outdoor fan
mode
High
High
Compressor
revolution
(rps)
47
72
Temperature
condition (°C)
Indoor Outdoor
20/ 7/6
Heat exchanger
pipe temp.
T1 (°C) T2 (°C)
37 to 38 2 to 4
42 to 44 0 to 3
Model
name
RAS-
10JKVP-E
13JKVP-E
Standard
pressure
P (MPa)
2.2 to 2.4
2.5 to 2.7
Indoor fan
mode
High
High
Outdoor fan
mode
High
High
Compressor
revolution
(rps)
61
79