8-2. Operation Description
Item
1. Basic
operation
Operation flow and applicable data, etc.
1) Operation control
Receiving the users operation condition setup, the opera-
tion statuses of indoor/outdoor units are controlled.
Description
1) The operation conditions are
selected by the remote controller as
shown in the left.
2) A signal is sent by ON button of the
remote controller.
3) The signal is received by a sensor of
the indoor unit and processed by the
indoor controllers as shown in the
left.
4) The indoor controller controls the
indoor fan motor and louver motor.
5) The indoor controller sends the
operation command to the outdoor
controller, and sends/receives the
control status with a serial signal.
6) The outdoor controller controls the
operation as shown in the left, and
also controls the compressor,
outdoor fan motor, 4-way valve and
electronic control valve.
2) Cooling/Heating operation
The operations are performed in the following parts by
controls according to cooling/heating conditions.
1) Receiving the operation ON signal of
the remote controller, the cooling or
heating operation signal starts being
transferred form the indoor controller
to the outdoor unit.
2) At the indoor unit side, the indoor fan
is operated according to the con-
tents of 3. Indoor fan motor control
and the louver according to the
contents of 6. Louver control,
respectively.
3) The outdoor unit controls the
outdoor fan motor, compressor,
electronic control valve and 4-way
valve according to the operation
signal sent from the indoor unit.
*1. The power coupler of
4-way valve is usually turned on,
and it is turned off during defrost
operation. (Only in heating)
Remote controller
Indoor unit
Control contents of remote controller
ON/OFF (Air conditioner/Air filter)
Operation select
(COOL/HEAT/AUTO/DRY)
Temperature setup
Air direction
Swing
Air volume select
(AUTO/LOW/LOW+/MED/MED+/HIGH)
ECO
ON timer setup
OFF timer setup
Powerful
Signal
receiving
Indoor unit
control
Indoor unit control
Command signal generating
function of indoor unit operation
Calculation function
(temperature calculation)
Activation compensation
function of indoor fan
Cold draft preventive function
Timer function
Indoor heat exchanger
release control
Operation
command
Serial signal
send/receive
Indoor fan motor
Louver motor
Outdoor unit
Outdoor unit control
Frequency control of inverter output
Waveform composite function
Calculation function
(Temperature calculation)
AD conversion function
Quick heating function
Delay function of compressor reactivation
Current release function
GTr over-current preventive function
Defrost operation function
Compressor
Outdoor fan motor
4-way valve
Electronic control valve
Selection
of operation
conditions
ON/OFF
Serial signal
send/receive
Outdoor unit
control
Operation ON
Setup of remote controller
Indoor fan motor
Control of No. of revolution
Louver control
Control of No. of revolution of compressor
Outdoor fan motor control
4-way valve control
In cooling operation: OFF
In heating operation: OFF
Electronic control valve control
Indoor unit
control
Sending of
operation
command signal
Outdoor unit
control
Inverter
~
[ ]