EasyManua.ls Logo

Toshiba RAS-10NAV-E - Outdoor Unit; 5 Specification of Electrical Parts; Indoor Unit

Toshiba RAS-10NAV-E
77 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FILE NO. SVM-05026
– 17 –
5-1. Indoor Unit
5-2. Outdoor Unit
5. SPECIFICATION OF ELECTRICAL PARTS
No. Parts name Model name Rating
1 SC coil L01 ADR2516-0R6TB 0.6mH, 15A
(Noise filter) L03 ADR2510-020T4B 10A, 2mH
Primary side DC280V, Secondary2 DC-DC transformer
SWT-72
side 7.0 V x 1, 12 V x 1, 17V x 2
3 Reactor CH-51-Z-T L=19mH, 10A
4 Outside fan motor
HF-240-20B-2 20W
5
G5NB-1A Coil DC12V Contact AC250V-1.5A
6
Outside air temp.
(Inverter attached) 10k (25°C)
sensor (TO sensor)
7
Heat exchanger temp.
(Inverter attached) 10k (25°C)
sensor (TE sensor)
9
JX0-6B
20A, AC250V
Terminal block (6P)
10
11
Fuse
For protection of switching power source 3.15A, AC250V
For protection of inverter input overcurrent 25A, AC250V
12
Electrolytic capacitor LLQ2G761KHUBTF 760µF, DC 400 V x 3 pieces
13
Compressor thermo. PW-2AL OFF: 125 ± 4°C, ON: 90 ± 5°C
Rectifier
14
Fan control relay
D25XB60-4001 20A, 600V
16 4-way valve coil SQ583
AC220-240V
IGBT GT20J321 20A, 600
Compressor DA89X1F-23F 3-phases 4-poles 750W
15
8
Dischenge temp.
(Inverter attached) 62k (20°C)
sensor (TD sensor)
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150°C thermo fuse
2 Thermo. sensor (TA-sensor) 10 k at 25°C
3 AC-AC transformer (T01) TT-10 187 - 276V, 6VA
4 Microcomputer
5 Heat exchanger sensor
10 k at 25°C
(TC-sensor)
6 Line filter (L01) SS11V-06270 27 µ
7 Diode (DB01) KBP06M 1.5A, 420V
8 Capacitor (C50)
9 Fuse (F01) BET 3.15A 250VAC T3.15A, 250 V
10 Regulator IC (IC08) NJM7812 12VDC, 1.5A max
12 Varistor (R21, R109) 15G561K 560 V
13 Louver motor 24BYJ48 DC 12V
µPD780024AGK
LXV35VB2200MJ20 2200 µ F, 35V
11 Regulator IC (IC11) NJM7805 5VDC, 1.5A max
H, AC 0.64A