− 11 −
FILE NO. SVM-06027
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (
RAS-13GKHP-ES2,
RAS-13NKHP-AS2)
4-2. Outdoor Unit (RAS-13GAH-ES2, RAS-13N2AH-AS2)
No. Parts name
Type
Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 − 240V, 50Hz
1 Compressor PA150X2C-4FT Winding resistance (Ω) C-R C-S
(at 20°C) 2.35 3.22
Output (Rated) 42W, 6poles, 1 phase, 220 − 240V, 50Hz
2
Fan motor
HF-240-42A or
Winding resistance (Ω) Red-Black White-Black
(at 20°C) 176.2 or 188
290.5 or 289
3
Running capacitor
DS451155NPQB AC 450V, 1.5µF
(for fan motor)
4
Running capacitor
RS44B306U0214S AC 440V, 30µF
(for compressor)
Solenoid coil
5
AC 220 − 240V, 50Hz
(for Heat pump
WLF-240-42A
(for outdoor)
(for 4-way valve)
model)
STF-01AJ503H1
µRM1260V
DC 390V, Secondary DC 12V
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF-220-20-4A-1 AC Motor with 150 C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Micro Power Module (M01)
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60 4A, 600 V
8 Capacitor (C63) KMH400VSSN47M22S 47mF, 400 V
9 Fuse (F01) BET 6.3A T6.3A, 250VAC
10 Varistor (R21, R22) TND15G561K 560 V
11 Resistor (R319) RF-2TK5R6 5.6 , 2 W
12 Louver motor MP24Z 12VDC
13 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 3-48VDC
14 Relay (Fan, RY03) G5NB-1A Rating 3A/AC250 V, 12VDC
15 Relay (Solenoide, RY04) G5NB-1A Rating 3A/AC250 V, 12VDC
W
W
W
°
°
°