31 −
FILE NO. SVM-06027
Part
Code
A
B
C
Q'ty
One
each
1
One
each
Parts name
8-3. Installation
8-3-1. Optional installation parts
<Fixing bolt arrangement of outdoor unit>
Fig. 8-3-1
Secure the outdoor unit with fixing bolts and nuts if the unit is likely to be exposed to a strong wind.
Use 8 mm or 10 mm anchor bolts and nuts.
If it is necessary to drain the defrost water, attach 9 drain nipple and 10 cap water proof to the
bottom plate of the outdoor unit before installing it.
FIL E NO. SV M-02001(2)
600 mm
90 mm
125 mm
108 mm
32.5 mm
86 mm
102 mm
320 mm
7 mm
3
0
Air outlet
Air inlet
Drain outlet
Refrigerant piping
Liquid side : 6.35 mm
Gas side 12.7 mm
:
Pipe insulating material
(polyethylene foam, 6 mm thick)
Putty, PVC tapes