− 12 −
4-4. Outdoor Unit (RAS-13GA-ES2, RAS-13N2A-AS2)
No. Parts name Type Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220 − 240V, 50Hz
1 Compressor
PA150X2C-4FT
Winding resistance (Ω) C-R C-S
(at 20°C)
2.35
3.22
Output (Rated) 30W, 6poles, 1 phase, 220 − 240V, 50Hz
2
Fan motor
(for outdoor)
WLF-240-30A
Winding resistance (Ω) Red-Black White-Black
(at 20°C) 237
380
3
Running capacitor
DS451155NPQB
AC 450V, 1.5µF
(for fan motor)
4
Running capacitor
RS44B306U0214S
AC 440V, 30µF
(for compressor)
4-3. Indoor Unit (RAS-13GKP-ES2, RAS-13NKP-AS2)
FILE NO. SVM-06027
No. Parts name Type Specifications
1 Fan motor (for indoor) SKF- 220-20-4A-1 AC Motor with 150 C thermo fuse
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Transformer
4 Microcontroller unit (IC30) TMP87CM40AN
5 Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01) *SS11V-06270 27mH, 600mA
7 Bridge rectifier (DB50) KBP06M/51 1.5A, 600 V
8 Capacitor (C50) PF1E222MNN1625 2200mF, 25 V
9 Fuse (F01) BET6.3A T6.3A, 250VAC
10 Varistor (R21, R22)
TND15G561K
560 V
11 Louver motor MP24Z 12VDC
12 Relay (Comp., RY01) DI1U Rating 25A/AC250 V, 3~48VDC
W
°
°
°
W
TT-10