− 14 −
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Heat exchanger
Propeller fan
Outdoor unit
Capillary tube
∅1.7x700
PA150X2C-4FT
Cooling
Mark( )means check points of Gas Leak.
O.D.:12.7mm O.D.:6.35mm
Cooling
Packed valve
(∅12.7)
Packed valve
(∅6.35)
0.39m
(Connecting pipe)
∅12.7
0.49m
(Connecting pipe)
∅6.35
T1
P
Refrigerant
R410A : 0.98 kg.
5-2. RAS-13GKP-ES2 / RAS-13GA-ES2
Note :
•Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.80 10.0 High 27/19 35/24
Cooling Overload 1.04 15.0 High 32/23 43/26
Low temperature 0.72 2.0 Low 21/15 21/15
Fan speed
(indoor)
50Hz
Standar d
pressure
P
(MPaG)
Surface temp. of heat
exchang er inter changing
pipe
T1
(°C)
l
FILE NO. SVM-06027
Accumulator
RAS-13NKP-AS2 / RAS-13N2A-AS2