4 Replacement Procedures 4.3 HDD
4-12 Satellit /Satellite Pro /C850D/C855D /L850D/L855D Maintenance Manual
NOTE: Do not disassemble the HDD pack when it is working normally. Disassemble
or replace the HDD pack only if it fails.
4. Place the HDD pack on a flat surface (such as a desk), and remove the four M3x3.5
black flat head screws.
5. Place the HDD pack on a flat surface (such as a desk), and remove the chassis.
HDD pack
HDDchassis
M3 0x3 5 black flat head screw. .
Figure 4-4 Removing the HDD chassis
CAUTION: Do not apply pressure to the top or bottom of the drive.