Strata CTX Configuration
Worksheet 3: CO Line
Strata CTX I&M 10/02 1-25
Strata CTX
Configuration
Worksheet 3: CO Line
Main Location _______________ Remote Location 1___ 2___ 3___ 4____5___ 6____
Item
#
Co Line Type Required
Line
Qty
/X=
PCB
Qty
PCB
Name
Slots Required
1
1. Round up fractions to the nearest whole number.
CO1 Analog Loop Start CO Lines with RCOU /4= RCOU 1 Slot/RCOU =
CO2
Analog Loop Start CO Lines with RCOU/
RCOS
/8=
RCOU/
RCOS
1 Slot/RCOU/RCOS =
CO3
Analog Ground Start CO Lines with
RGLU
/4= RGLU 1 Slot/RGLU =
CO4 Caller ID Line interface with RCIU /4= RCIU 1 Slot/RCIU =
CO5 Caller ID Line interface with RCIU/RCIS /8=
RCIU/
RCIS
1 Slot/RCIU/IS =
CO6 BVPU VoIP Circuits
2
2. Maximum of five PCBs with CTX670 and two BVPU PCBs with CTX100 because of FCC Part 15 emissions requirement.
/4= BVPU 1 Slot/BVPU =
CO7 Analog Tie Lines with REMU /4= REMU 1 Slot/REMU =
CO8 Analog DID Lines with RDDU /4= RDDU 1 Slot/RDDU =
CO9 T1 Digital Lines with RDTU2 /24= RDTU2 2 Slots/RDTU2 =
CO10 T1 Digital Lines with RDTU2 /16= RDTU2 1 Slot/RDTU2 =
CO11 T1 Digital Lines with RDTU2 /8= RDTU2 1 Slots/RDTU2 =
CO12 ISDN and/or QSIG with RPTU2 /23 RPTU2 1 Slot/RPTU2 =
CO13 ISDN and/or QSIG with RPTU2 /16 RPTU2 1 Slot/RPTU2 =
CO14 ISDN and/or QSIG with RPTU2 /8 RPTU2 1 Slot/RPTU2 =
CO15 ISDN BRI Circuit
3
, U-type with RBUU
3. Each ISDN BRI circuit can be configured to provide two CO lines or interface to one BRI station. Each circuit uses 2 CO lines and
2 station ports of system capacity regardless of how it is configured (line or station).
/2= RBUU 1 Slot/RBUU =
CO16
ISDN BRI Circuits
1
, U-type with RBUU/
RBUS
/4=
RBUU/
RBUS
1 Slot/RBUU/US =
CO17 ISDN BRI Circuits
1
, S/T-type with RBSU /2= RBSU 1 Slot/RBSU =
CO18
ISDN BRI Circuits
1
, S/T-type with RBSU/
RBSS
/4=
RBSU/
RBSS
1 Slot/RBSU/RBSS =
CO19
E911 CAMA Circuits (RMCS/RCMS=2
circuits, add another RCMS for 4 circuits
/4=
RMCU/
RCMS
1 Slot/RMCU/RMMS=
CO20 Total Slots required for line PCBs
Miscellaneous CO Line Equipment
CO21
Dealer-supplied NT-1 S/T BRI Line
Circuits
Number of NT-1s No slots required.
CO22
Dealer-supplied CSU for RPTU and/or
RDTU2
Number of CSUs No slots required.
CO23 Cable kits for RPTU2 Number of RPRI-CBL-KIT No slots required.
CO24 Cable Kits for RPTU2 Number of RPRI-CBL-KIT No slots required.
CO23
Secondary Protectors For RDDU and
REMU
Number of Protectors. No slots required.