EasyManua.ls Logo

Toshiba Strata CTX670 - Analog Loop Start Lines with or Without Caller ID

Toshiba Strata CTX670
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Strata CTX Configuration
CTX100 Maximum Capacity Configuration Examples
1-28 Strata CTX I&M 10/02
Analog Loop Start Lines with or without Caller ID
Table 1-13 CTX100 Base: 32 stations, 8 loop start lines, 8 CLID
S101 S102 S103 S104
BDKU/
BDKS
BDKU/
BDKS
RCOU/
RCOS
RCIU/RCIS
16 DKTs 16 DKTs 8 lines 8 CLID
Table 1-14 CTX100 Base: 32 stations, 16 loop start lines, 0 CLID
S101 S102 S103 S104
BDKU/
BDKS
BDKU/
BDKS
RCOU/
RCOS
RCOU/
RCOS
16 DKTs 16 DKTs 8 lines 8 lines
Table 1-15 CTX100 Base: 16 stations, 16 loop start lines, 8 CLID
S101 S102 S103 S104
BDKU/
BDKS
RCOU/
RCOS
RCOU/
RCOS
RCIU/RCIS
16 DKTs 8 lines 8 lines 8 CLID
Table 1-16 CTX100 Base: 24 stations with ADKU, 8 loop start lines, 0 CLID
S101 S102 S103 S104
ADKU ADKU ADKU
RCOU/
RCOS
8 DKTs 8 DKTs 8 DKTs 8 lines
Table 1-17 CTX100 Base and Expansion Cabinet with Analog Loop Start Lines
8 Universal Slots
72 Stations (Max.)
56 CO lines (Max.)
92 Stations + Analog Loop Start Lines combined (Max.)
Table No. Stations Analog loop start lines
1-18 72 20 (none can have Caller ID)
1-19 72 16 (8 can have Caller ID)
1-20 64 32 (none can have Caller ID)
1-21 64 24 (8 can have Caller ID)
1-22 64 16 (all can have Caller ID)
1-23 48 40 (none with Caller ID)
1-24 48 32 (8 can have Caller ID)
1-25 48 24 (16 can have Caller ID)
1-26 32 48 (none can have Caller ID)
1-27 32 40 (8 can have Caller ID)
1-28 32 32(16 can have Caller ID)
1-29 32 24 (24 can have Caller ID)
1-30 16 32 (24 can have Caller ID)

Table of Contents