E6582051
- 1 -
Introduction
Thank you for purchasing the PROFINET
option “PNE001Z” for VF-S15 (CPU1 version 112 or
later) ,VF-AS3 and VF-MB1 (CPU1 version 116 or later) . Before using the PROFINET option, please
familiarize yourself with the product and be sure to thoroughly read the instructions and precautions
contained in this manual.
In addition, please make sure that this manual and “Precautions Manual” (E6582052) is delivered to the
customer, and keep this function manual in a safe place for future reference or drive/interface inspection.
This manual describes the supported functions for the “PNE001Z”.
In conjunction with this manual, the following manuals are supplied by Toshiba, and they are essential
both for ensuring a safe, reliable system installation as well as for realizing the full potential of the
“PNE001Z”:
- TOSVERT VF-S15 Instruction Manual .......................................................... E6581611
- TOSVERT VF-MB1 Instruction Manual ......................................................... E6581697
- VF-MB1/S15/AS3 communication option Precautions Manual ········· ········ E6582052
- TOSVERT VF-AS3 Instruction Manual.......................................................... E6582062
PROFINET is a registered trademark of PROFIBUS Nutzerorganisation EV.
Modbus is a registered trademark of Schneider Automation.
Other product names may be trademarks or registered trademarks of their respective owners.

Table of Contents

Other manuals for Toshiba Tosvert VF-S15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba Tosvert VF-S15 and is the answer not in the manual?

Toshiba Tosvert VF-S15 Specifications

General IconGeneral
CategoryInverter
Control MethodV/f control, Sensorless vector control
Cooling MethodForced air cooling
ModelTosvert VF-S15
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Communication OptionsModbus RTU
Overload Capacity150% for 1 minute
Braking UnitBuilt-in braking transistor
Output Voltage3-Phase, same as input voltage
Operating Temperature-10 to +50°C (14 to 122°F)
Storage Temperature-20 to 65°C (-4 to 149°F)
Humidity5 to 95% RH (non-condensing)
AltitudeUp to 1000m above sea level
Input Voltage3-Phase 200 to 240 VAC, 3-Phase 380 to 480 VAC
WeightVaries depending on model (e.g., 0.8 kg to 16 kg)