4.7 Resetting to factory settings
Returning to the factory settings can only be initiated during power-up.
To do this, during power-up the MEM and DUAL buttons must be pressed simultaneously and the
display will show “SET DEFAULTS”. When the buttons are released the resetting to the factory set-
tings takes place. When resetting is completed “DONE” is displayed.
4.8 SET UP - Menu
During power-up the MEM button must be pressed.
The message "protect mode" is displayed, just wait until it changes.
There are two functions available within the Set-up menu:
ERASE Erasing of the favorites (frequency and identifier)
Channel Spacing 25kHz / 8,33kHz
Programming of the Set-up is done with the lower 3 buttons next to the symbols (Exit, S, E). Their
function is described on the display.
To exit the SET-UP menu, use the MEM button. The unit remains powered and the normal operating
mode is resumed.