24
8. Specifications TQC Sheen Glossmeter
Applied products:
GL0010 TQC Sheen SoloGloss 60˚
GL0020 TQC Sheen DuoGloss 20˚
60˚
GL0030 TQC Sheen PolyGloss 20˚
60˚/85˚
Measurement:
Base dimensions: 45 x 130mm / 1.7 x 5.1 inch
Orifice size: 10 x 50mm / 0.4 x 2.0 inch
Spot size: ±5 x 5 mm / @ 20˚ / 0.2 x 0.2 inch
±20 x 9 mm / @ 60˚ / 0.8 x 0.35 inch
±40 x 9mm / @ 85˚ / 1.5 x 0.35 inch
Measurement speed: 70 measurements per minute at 3 angles
Simultaneous measurement: 3 geometries
Power saver option: User selectable
Units: Gloss Units (GU)
Resolutions: 0.1 GU (0-100GU)
1 GU (>100GU)
Measuring angle characteristics:
20˚ 60˚ 85˚
Range 0-2000 GU 0-2000 GU 0-2000 GU
Repeatability r * 0,4 GU 0,2 GU 0,2 GU
Reproduceability R * 1,69 GU 1,58 GU 1,88 GU
Bias 1,2 GU 0,6 GU 1,6 GU
* According to ISO 2813 (range 0-100 GU)
Operational:
Calibration standard: Integrated tile in dust cover
Display: High Contrast OLED display
Batches: Max. 8
Readings per batch: 500, non-dependent on number of angles.
Readings max. 2000
Scan function: Yes
Statistics: Min. / Max. / Avg. / Std.dev
Security: Password protection
Software: TQC Sheen Ideal Finish Analysis