33
CLEARING NOTIFICATIONS
Afer you address the issue listed in the notification, you can clear notifications with the Menu - Settings - Clear Notifications menu item.
ERROR MESSAGE SOLUTION
AUGER OVERCURRENT
This error will occur if the auger motor is damaged or jammed. Use the Clear Auger feature inside
the control menu and restart your grill. If the problem continues, you may need to replace your
auger motor. Go to traeger.com/support or contact customer service (see page 36) for further
troubleshooting. Make sure your grill is connected and on the latest firmware.
LOW AMBIENT TEMP
This warning will occur when the ambient temperature at the controller falls below -20°F (-29°C) for
30 seconds. This would likely only display if the LCD heater is broken. The error is cleared once the
grill warms up above -20°F (-29°C).
INSERT PROBE
This message will occur during a custom cook if the probe is required and disconnected. Insert the
probe into the controller to clear the message.
LOW TEMP DETECTED“LOW TEMP
DETECTED”
This message will occur if grill temperature drops below the set temperature for 4 minutes. This is not
necessarily a problem; the grill is just communicating a low temperature detection. If the grill cannot
recover from this state, you will likely get a low temp error (LEr) (see page 32). Make sure your grill is
connected and on the latest firmware.
THERMOCOUPLE DISCONNECTED
ERROR –“TEMP SENSOR OUT”
This error will occur when the controller is no longer getting a reading from the thermocouple. This is
caused by the thermocouple connection on the back of the controller becoming disconnected, a bad
wire, or a faulty thermocouple. Go to traeger.com/support for steps on how to check the connection.
Make sure your grill is connected and on the latest firmware. If issues persist, contact customer
service (see page 36).
PELLET LEVEL LOW ERROR –
“PELLET LEVEL LOW”
This error will occur when pellet sensor detects the pellet level is at or below 25%. Fill with pellets to
remove this message.
PELLET LEVEL CRITICAL ERROR –
ADD PELLETS”
This error will occur when pellet sensor detects the pellet level is at 0%. Fill with pellets to remove
this message. Not filling with pellets could result in a low temp error (LEr) (see page 32).
LOW TEMP WARNING
This warning will occur if the grill has lost its fire and failed to recover. Check the pellets and restart
the grill.
IGNITION WARNING
(APP NOTIFICATION ONLY)
This warning will occur if the grill has not detected a successful ignition in the expected time. Check
the pellets and restart the grill.
COLD WEATHER STARTUP
This warning will occur when the ambient temperature falls below -20°F (-29°C) for more than
30 seconds. Although the controller will still work, damage to the controllers display may have
occurred. If the grill ignites, check to see if the display operates as expected. If the grill does not
ignite, warm the grill and check to see if the display and controller operate as expected. Make sure
your grill is connected and on the latest firmware. If not, contact customer service (see page 36).
PROBE FELL OUT
This warning will occur if the probe is not properly inserted into the food. The message is triggered
when the probe is above 220°F (104°C) while the grill is running. Reinsert the probe into your food as
instructed on pages 24-25.
BAD PROBE
This warning will occur if the controller detects a malfunction in the probe for 10 seconds.
The probe will need to be replaced. To order a new probe, go to traeger.com or contact customer
service (see page 36).
T09627_Redland_OM_EN.indd 33T09627_Redland_OM_EN.indd 33 9/16/22 10:59 AM9/16/22 10:59 AM