18-EB40D1-1E-EN
11
11. Exhaust vents or other sources of contaminated air
should not be near the unit’s air inlet if outside air is
to be introduced as make-up air or a ventilation
feature is to be used. Contamination from exhaust
vents or chimneys may also foul the condenser
causing degraded performance.
12. Check the handling facilities to ensure the safety of
personnel and the unit(s).
13. Manufacturer allows the use of the furnace during
the finishing stages of construction, given the
workspace is substantially free of debris and dust;
interior drywall installation shall be completed and
covered with paint or primer; proper vent
installation; furnace shall be set up to operate in
accordance with the manufacturer’s shipped
installation instructions and shall be verified for
operating conditions including ignition, input rate,
temperature rise, and venting.
CClleeaarraanncceess
1. The recommended clearances for single-unit
installations are illustrated in Determine Unit
Clearances,” p. 8.
2. Any reduction of the unit clearances indicated in
these figures may result in condenser coil
starvation or the recirculation of warm condenser
air. Actual clearances, which appear to be
inadequate should be reviewed with a local
engineer.
3. See the unit’s nameplate for the absolute minimum
clearance between the unit and any combustible
surfaces.
4. The vent of this unit must not terminate above
grade, veranda, porch, deck, or balcony within 12”
(30 cm); Clearance to window or door that can be
opened minimum distance 12” (30 cm); Clearance
to any permanently closed window follow Install
manual Instructions. Hot gases leaving the unit vent
can affect all construction materials and must be
evaluated by installer.
RReevviieeww LLooccaattiioonn aanndd RReeccoommmmeennddaattiioonn IInnffoorrmmaattiioonn

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane 4YCC4048E1070A and is the answer not in the manual?

Trane 4YCC4048E1070A Specifications

General IconGeneral
BrandTrane
Model4YCC4048E1070A
CategoryAir Handlers
LanguageEnglish