Unit Dimensions
DIMENSIONAL DATA
20"[508]
20"[508]
20"[508]
26"[660]
26"[660]
26"[660]
30"[762]
30"[762]
14-1/2"[368]
17-1/2"[445]
21"[533]
17-1/2"[445]
21"[533]
24-1/2"[622]
21"[533]
24-1/2"[622]
13"[330]
16"[407]
19-1/2"[495]
16"[407]
19-1/2"[495]
23"[584]
19-1/2"[495]
23"[584]
3/8" / 3/4"
3/8" / 3/4"
3/8" / 3/4"
3/8" / 7/8"
3/8" / 7/8"
3/8" / 7/8"
3/8" / 7/8"
3/8" / 7/8"
44[20]
46[21]
49[22]
57[26]
59[27]
64[29]
81[37]
86[39]
MODELS UNIT HEIGHT
"H" (in [mm])
UNIT WIDTH
"W" (in [mm])
SUPPLY
DUCT "A"
(in [mm])
LIQUID LINE/
VAPOR LINE
WEIGHT
(lb [kg])
Table 2-1
2.2 Codes & Regulations
2.3 Inspection upon Unit Arrival
This product is designed and manufactured to comply
with national codes.
Installation in accordance with such codes and/or
prevailing local codes/regulations is the responsibility of
the installer. The manufacturer assumes no
responsibility for equipment installed in violation of any
codes or regulations.
The United States Environmental Protection
Agency(EPA) has issued various regulations regarding
the introduction and disposal of refrigerants. Failure to
follow these regulations may harm the environment and
can lead to the imposition of substantial fines. Should
you have any questions please contact the local office of
the EPA.
As soon as unit is received, it should be inspected and
noted for possible shipping damage during transportation.
It is the carrier's responsibility to cover the cost of
shipping damage. Manufacturer or distributor will not
accept a claim from contractors for any transportation
damage.
2.4 Clearances
Following clearances should be provided during
installation
a.Maintenance and service access, including coil
cleaning and coil assembly removal
b.Refrigerant piping and connections
c.Condensate drain line
To ensure the proper installation, it is important to Select
a solid and level site.
Ensure that there is enough space required for
installation and maintenance.
≥20"
Fig. 2-2 Front view of the indoor unit clearance
(including air duct)
Fig. 2-3 Top View of the indoor unit clearance (including
air duct)
≥24"
≥1"
≥0
≥1"
5MXCA003AC6HCA
5MXCB004AC6HCA
5MXCC005AC6HCA
5MXCB006AC6HCA
5MXCC007AC6HCA
5MXCD008AC6HCA
5MXCC009AC6HCA
5MXCD010AC6HCA