Installation Guide
10 18-HD98D1-1B-EN
Sub Menu Menu Selection
Options [Default]
Description
General
System
Operation
Heating Aggressive
Recovery Setting (°F)
0°F -70°F [40°F]
Select the outdoor temperature for
Heating Aggressive Recovery.
Smart Control Fan
Enable Status
Enabled/[Disabled]
Select to enable or disable Smart
Continuous Fan.
System
Controller
SC360 Installed in
Conditioned Space
Yes/[No]
Enable if the SC360 was installed in a
conditioned space and can be used as an
indoor temperature and humidity sensor.
Indoor Heat
Heater Type
[None]/Electric/
Hydronic
Select the type of indoor unit
installed. Value is pre-populated for
communicating equipment.
Heater Size
Electric: [Empty List]/
25KW, 1-Phase/
20KW, 1-Phase/
15KW, 3-Phase/
15KW, 1-Phase/
10KW, 3-Phase/
10KW, 1-Phase/
8KW, 1-Phase/ 4KW,
1-Phase/
5KW, 1-Phase
Hydronic:
100Kbtu/80Kbtu/
70Kbtu/50Kbtu
Select the size of the indoor unit based
on tonnage and heater type. Options
vary depending on heater type.
Value is pre-populated for
communicating equipment.
Heater Model Number [NOMODELNUM]
Value is pre-populated based on heater
size, but can also be manually configured.
Heater Serial Number [NOSERNUM]
Enter the 10-digit serial number of the
indoor unit.
Cycles Per Hour 2-6 CPH [5]
Electric Heat Airflow [Low]/Med/High
Blower On Delay
No delay/15/30/45/[60]
seconds
Select to enable or disable the blower
on delay in hydronic heating.
Blower Off Delay
No delay/30/[50]/70/90
seconds
Select to enable or disable the blower
off delay in hydronic heating.
Compressor
Operation
Minimum System
Speed
[Factory]/
30%/40%/50%
Compressor
Cooling
Cycles Per Hour 2-6 CPH [3]
Blower Off Delay
[No Delay]/Auto/
30 seconds
Select to enable or disable the blower
off delay in compressor cooling.
Blower On Delay
[No Delay]/Auto/
30 seconds
Select to enable or disable the blower
on delay in compressor cooling.
Minimum Indoor Coil
Temp (°F)
28°F -60°F [30°F]
Maximum Indoor Coil
Temp (°F)
28°F -60°F [55°F]