Installation Guide
12 18-HD98D1-1B-EN
8.5 Accessories
Sub Menu Menu Selection
Options [Default]
Description
Accessory 1
& 2 Input
Accessory Type
[None], Air Cleaner,
Powered/Bypass,
Steam, Ext Dehum,
Ventilator
Select the accessory type.
Humidifier Action
[With Active Heat Call],
Without Active Heat
Call
Disabled for Air Cleaner accessory.
Airflow During
Humidifier Only Mode
35%-100% [50%]
Select the desired airflow when the
humidifier is operating without an
active call for heat.
Dehum Type
[With Cool]/Stand alone
Defaulted to [With Cool] for Ext Dehum
accessory.
Dehum Fan Action [Force Fan]/Normal
Minimum Ventilation
Run Time (mins)
1-60 [5]
Ventilator Fan Action
[Ventilate With Blower]/
Ventilate Without
Blower
Outdoor Temperature
Ventilation Override
[Disabled]/Enabled
Max Outdoor
Temperature
80°F - 110°F [85°F]
Min Outdoor
Temperature
-10°F to 50°F [0°F]
Accumulate
Overridden Run Time
[Disabled]/Enabled
Accumulate Period
[4 hrs - Recover
based on OD
Conditions]/4 hrs -
Recover to maintain
Min Ventilation/24 hrs
- Recover based on
OD Conditions/24 hrs
- Recover to maintain
Min Ventilation
Humidifier Control
[RH Control]/Frost
Control
Not available for Ext Dehum accessory.
Available accessory menu selections will vary based on the accessory type.