S9V2-SVX001-1A-EN
19
Table 7. S9V2B040U3PSBC/D / S9V2B040D3PSBC/D Cooling Airflow (continued)
S9V2B040U3PSBC/D / S9V2B040D3PSBC/D Furnace Cooling Airflow (CFM) and Power (Watts) vs. External Static
Pressure with Filter (iwc)
Cooling
Unit
Outdoor
Airflow
Setting
(CFM/ton)
External Static Pressure
0.1 0.3 0.5 0.7 0.9
Cooling
2.5 Ton
Cooling 450
CFM/Ton
CFM 1125 1125 1125 1125 1125
Watts 167 219 278 341 408
Cooling 420
CFM/Ton
CFM 1050 1050 1050 1050 1050
Watts 139 188 244 304 368
Cooling 400
CFM/Ton
CFM 1000 1000 1000 1000 1000
Watts 123 170 223 281 343
Cooling 370
CFM/Ton
CFM 925 925 925 925 925
Watts 100 145 195 250 308
Cooling 350
CFM/Ton
CFM 875 875 875 875 875
Watts 87 129 178 230 287
Cooling 330
CFM/Ton
CFM 825 825 825 825 825
Watts 121 160 205 254 308
Cooling 310
CFM/Ton
CFM 775 775 775 775 775
Watts 101 139 182 229 281
Cooling 290
CFM/Ton
CFM 725 725 725 725 725
Watts 88 123 164 210 260
Cooling
3.0 Ton
(a)
Cooling 450
CFM/Ton
CFM 1350 1350 1350 1298 1198
Watts 272 334 402 440 450
Cooling 420
CFM/Ton
CFM 1260 1260 1260 1260 1198
Watts 226 284 348 417 450
Cooling 400
CFM/Ton
CFM 1200 1200 1200 1200 1198
Watts 198 254 315 381 450
Cooling 370
CFM/Ton
CFM 1110 1110 1110 1110 1110
Watts 161 213 271 333 399
Cooling 350
CFM/Ton
(a)
CFM 1050 1050 1050 1050 1050
Watts 139 188 244 304 368
Cooling 330
CFM/Ton
CFM 990 990 990 990 990
Watts 119 166 219 277 338
Cooling 310
CFM/Ton
CFM 930 930 930 930 930
Watts 102 146 197 252 311
Cooling 290
CFM/Ton
CFM 870 870 870 870 870
Watts 86 128 176 229 285
(a)
Factory Setting.
Table 8. S9V2B060D3PSBC/D Heating Airflow
S9V2B060D3PSBC/D Furnace Heating Airflow (CFM), Temp. Rise (°F), and Power (Watts) vs. External Static Pressure
with Filter (iwc)
1st Stage Capacity = 37,700
2nd Stage Capacity = 57,850
Heating
Airflow
Setting
Target
Airflow
External Static Pressure
0.1 0.3 0.5 0.7 0.9
Heating 1st
Stage
Low 711
CFM 677 677 678 678 678
Temp. Rise
52 52 52 52 52
Watts 49 94 139 184 229
Medium Low
(a)
814
CFM 787 775 763 751 739
Temp. Rise
45 46 47 48 49
Watts 71 116 160 205 249
Medium 893
CFM 865 856 846 837 827
Temp. Rise
41 41 42 42 43
Watts 86 134 182 230 278
High
1067
CFM 1033 1013 994 974 955
Temp. Rise
35 35 36 36 37
Watts 141 193 245 297 349
Heating 2nd
Stage
Low 900
CFM 859 856 853 850 847
Temp. Rise
63 63 63 63 63
Watts 90 139 188 237 287
Medium Low
(a)
1030
CFM 977 967 958 948 938
Temp. Rise
55 56 57 57 58
Watts 126 179 232 285 338
Medium 1130
CFM 1067 1053 1040 1027 1013
Temp. Rise
51 52 52 53 54
Watts 162 219 275 332 388
High
1350
CFM 1246 1234 1222 1209 1197
Temp. Rise
44 44 44 45 45
Watts 279 333 387 440 494
(a)
Factory Setting.