24
CG-SVX039C-GB
CXAF CXAF CXAF CXAF CXAF CXAF CXAF
80 90 100 80 90 100 110
SSE SSE SSE SE SE SE SE
Option Additional shipping weight (6)
Single pump - Standard head
pressure
(kg) 257 257 257 254 254 254 264
Single pump - High head pressure (kg) 304 304 304 301 301 301 301
Twin pump - Standard head pressure (kg) 346 346 346 343 343 343 363
Twin pump - High head pressure (kg) 428 428 428 425 425 425 425
XLN option (kg) 114 114 114 114 114 114 114
Pump VFD option (kg) 70 70 70 70 70 70 70
Water Buffer tank option (kg) 286 286 286 286 286 286 286
System data
Nb of refrigerant circuit # 2 2 2 2 2 2 2
Minimum cooling load % (6) % 25 23 25 25 23 25 22
Total number of capacity steps # 4 8 4 4 8 4 8
Standard/Partial Heat Recovery Unit
R410A refrigerant charge
Circuit 1 / Circuit 2
(kg) 36/36 36/36 36/36 42 / 42 42 / 42 42 / 42 43 / 43
Oil charge Circuit 1 / Circuit 2 (l) 16.1 / 16.1 16.2 / 16.2 16.4 / 16.4 17.1 / 17.1 17.2 / 17.2 17.4 / 17.4 17.4 / 17.4
POE Oil type OIL058E / OIL057E
(1) Indicative performance at Evaporator water temperature : 12°C / 7°C - Condenser air temperature 35°C for cooling & Condenser water temperature:
40°C / 45°C - Evaporator air temperature 7°C (6°C) - for detailed performances, on a given unit, consult Order Write Up.
(2) Under 400V/3/50Hz.
(3) Rated Condition without Pump Package.
(4) Electrical & system data are indicative and subject to change without notice. Please refer to unit nameplate data.
(5) If the power line of the unit is protected by fuses gG of the same size as the disconnect switch.
(6) For detail information refer submittal drawing which are available in the unit.
General Data
Table 5 – General data CXAF 080-110 Standard Efficiency (continued)