21
Section 10. Refrigerant Line
10.1 Refrigerant Line Connection Sizes
10.2 Refrigerant System Layout
Refrigerant Line Connection Sizes
Model
Vapor Line
Connection
Liquid Line
Connection
TAM7A0A24H21SB
3/4 3/8
TAM7A0B30H21SB
3/4 3/8
TAM7A0C36H31SB
7/8 3/8
TAM7A0C42H31SB
7/8 3/8
TAM7A0C48H41SB
7/8 3/8
TAM7A0C60H51SB, TAM7B0C60H51SA
7/8 3/8
Notes:
1. This table indicates the tubing connection diameters at the indoor coil. A field supplied reducing
coupling may be required.
2. All AHRI listed systems are tested with 25 feet of refrigeration tubing; the rated tubing diameters are
located in the electronic performance data system.
3. If the refrigeration lines exceed 60 feet in linear length and / or if alternate size refrigeration tubing
is present at the job, please consult SS-APG006-EN or 32-3312-**(latest version)
Table 10.1
EEV Stepper
Motor
Vapor Line
Liquid Line
Check Valve
Strainer
Note: Some future
models may not
have external check
valve.
Evaporator Temperature
Sensor (ET)
- located on 3/8" Aluminum
distributor tube
(orange wires)
Gas Temperature
Sensor (GT)
- located on copper
section of manifold
(black wires)