33
Dip Switch S2
Set the S2-1 and S2-2 dip switches for the
Cooling and Heating CFM/Ton.
S2
1
1
12345
12345
HP
2(Compressor)
2(Stages)
AC (System)
}
OUTDOOR
Capacity (Tons)
OUTDOOR
}
Torque
CFM/Ton
Cool OffDelay
}
INDOOR
CFM
+12V
R13
R14
R1
R4
1
U1
RNET 1
S1
on
on
S2
RNET 2
R
6
C22
C19
C
15
C
12
C18
C21
C10
D9
L1
R22
Airflow Control (AFC)
INDOORMODEL S21 S22
COOLING
CFM/TON
HEATING
CFM/TON
OFF OFF 400 430
OFF ON 360 390
ON OFF 380 410
ON ON 420 450
OFF OFF 400 430
OFF ON 360 390
ON OFF 380 410
ON ON 420 450
OFF OFF 370 420
OFF ON 350 400
ON OFF 390 440
ON ON 410 450
OFF OFF 370 400
OFF ON 330 360
ON OFF 350 380
ON ON 390 420
OFF OFF 350 400
OFF ON 330 380
ON OFF 370 420
TAM7A0C42H31SB
TAM7A0C48H41SB
TAM7A0A24H21SB
TAM7A0B30H21SB
TAM7A0C36H31SB
ON ON 390 440
OFF OFF 370 400
OFF ON 380 410
ON OFF 390 420
ON ON 400 430
TAM7A0C60H51SB
TAM7B0C60H51SA