EasyManuals Logo

Trane TCONT602AF22MA Installation Instructions

Trane TCONT602AF22MA
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TCONT602AF22MA
Programmable Comfort Control
Installation Instructions
18-HD37D1-1

Other manuals for Trane TCONT602AF22MA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Trane TCONT602AF22MA and is the answer not in the manual?

Trane TCONT602AF22MA Specifications

Temperature Ranges IconTemperature Ranges
heat temperature range40° to 90°F (4.5° to 32°C)
cool temperature range60° to 99°F (16° to 37°C)
operating ambient temperature32° to 120°F (0° to 48.9°C)
Humidity IconHumidity
operating relative humidity5% to 90% (non-condensing)
Electrical Ratings IconElectrical Ratings
W (O) heating voltage20-30 Vac
W (O) heating current0.02-1.0 A
W1 W2 heating voltage20-30 Vac
W1 W2 heating current0.02-0.5 A
Y cooling voltage20-30 Vac
Y cooling current0.02-1.0 A
Y2 cooling voltage20-30 Vac
Y2 cooling current0.02-1.0 A
G fan voltage20-30 Vac
G fan current0.02-0.5 A
X2 emergency heat voltage20-30 Vac
X2 emergency heat current0.02-1.0 A
F heat pump reset voltage20-30 Vac
F heat pump reset current0.02-0.5 A
Weight and Dimensions IconWeight and Dimensions
height3-9/16” (91 mm)
width5-13/16” (147 mm)
depth1-1/2” (38 mm)