heat temperature range | 40° to 90°F (4.5° to 32°C) |
---|---|
cool temperature range | 60° to 99°F (16° to 37°C) |
operating ambient temperature | 32° to 120°F (0° to 48.9°C) |
operating relative humidity | 5% to 90% (non-condensing) |
---|
W (O) heating voltage | 20-30 Vac |
---|---|
W (O) heating current | 0.02-1.0 A |
W1 W2 heating voltage | 20-30 Vac |
W1 W2 heating current | 0.02-0.5 A |
Y cooling voltage | 20-30 Vac |
Y cooling current | 0.02-1.0 A |
Y2 cooling voltage | 20-30 Vac |
Y2 cooling current | 0.02-1.0 A |
G fan voltage | 20-30 Vac |
G fan current | 0.02-0.5 A |
X2 emergency heat voltage | 20-30 Vac |
X2 emergency heat current | 0.02-1.0 A |
F heat pump reset voltage | 20-30 Vac |
F heat pump reset current | 0.02-0.5 A |
height | 3-9/16” (91 mm) |
---|---|
width | 5-13/16” (147 mm) |
depth | 1-1/2” (38 mm) |