In case of difficulty
“Cool On” or
“Heat On”
is flashing
• Compressor protection timeout is engaged. Wait 5 minutes for the
system to restart safely, without damage to the compressor.
Cannot change
system setting
to “Cool”
• Check Installer Setup, Function 1 (System Type), to make sure it is set to
match the installed cooling equipment (see page 8).
• Change Installer Setup, Function 12 (System Setting) to Man
ual or Auto
Changeover (see page 9).
“Heat On” is not
displayed
• Change the System Setting to Heat, and set the temperature level above
the current room temperature.
“Cool On” is not
displayed
• Change the System Setting to Cool, and set the temperature level below
the current room temperature.
Accessories & replacement parts
Please contact your distributor to order replacement parts.
Battery holder........................................................Part Number THT02506
Cover plate assembly ..........................................Part Number BAYCOVR700A
(Use to cover marks left by old thermostats.)
Specifications
Temperature Ranges
• Heat: 40° to 90°F (4.5° to 32°C)
• Cool: 60° to 99°F (16° to 37°C)
Operating Ambient Temperature
• 32° to 120°F (0° to 48.9°C)
Shipping Temperature
• -20° to 120°F (-28.9° to 48.9°C)
Operating Relative Humidity
• 5% to 90% (non-condensing)
Physical Dimensions
• 3-9/16” H x 5-13/16” W x 1-1/2” D
• 91 mm H x 147 mm W x 38 mm D
Electrical Ratings
Terminal Voltage (50/60Hz) Running Current
W (O) Heating 20-30 Vac 0.02-1.0 A
W1 W2 Heating 20-30 Vac 0.02-0.5 A
Y Cooling 20-30 Vac 0.02-1.0 A
Y2 Cooling 20-30 Vac 0.02-1.0 A
G Fan 20-30 Vac 0.02-0.5 A
X2 Emergency heat 20-30 Vac 0.02-1.0 A
F Heat pump reset 20-30 Vac 0.02-0.5 A