BMTK-SVN01D-EN
Hardware Installation
Tracker
Version 12
Building Automation System

Table of Contents

Questions and Answers

  • K
    Kelly LevySep 8, 2025
    What to do if Trane Tracker Version 12 Air Conditioner Tracker controller did not discover UCMs?
    • M
      Micheal EllisSep 8, 2025
      If the Tracker controller did not discover UCMs when initially started, verify the correct wiring of the Comm5 communication link (UCMs can only be discovered if Comm5 communication has been established). Allow at least 5 minutes for the controller to discover the UCMs.
  • A
    Angelica GallagherSep 10, 2025
    What to do if Trane Tracker Version 12 Air Conditioner touch screen beeps but does not progress?
    • S
      Shannon GeorgeSep 10, 2025
      If the touch screen beeps when touched but does not progress to the next screen, perform the procedures for calibrating the touch screen as described in the Tracker Building Automation System Controller Operations guide.
  • M
    Mary RamirezSep 12, 2025
    How to troubleshoot Trane Tracker Version 12 Air Conditioner Tracker controller not communicating by EIA-232 port?
    • E
      Emily Ayers DDSSep 12, 2025
      If the Tracker controller does not communicate via the EIA-232 port, verify that the cable is connected to the PC direct connect port. Ensure the correct cable is used and that the PC workstation uses Tracker controller software. Check for activity on the PC RX LED.
  • D
    Destiny WallaceSep 13, 2025
    How to fix Trane Tracker Version 12 Tracker controller not communicating by modem?
    • G
      glenncookSep 13, 2025
      If the Tracker controller does not communicate by modem, verify that the telephone cable is connected to the PC modem port. Make sure the phone line is analog, not digital. Then, perform the modem self-test procedure from the display module.
  • A
    Ashley BowmanSep 15, 2025
    Why is outdoor air temperature not reading correctly on my Trane Tracker Version 12?
    • M
      michael06Sep 15, 2025
      If the outdoor air temperature is not reading correctly on your Trane Air Conditioner, measure the resistance of the outdoor air temperature thermistor (preferably at the termination module) and check the measurement against the provided table. Also, inspect the location of the outdoor air temperature sensor.
  • J
    James FlynnSep 18, 2025
    How to adjust touch-screen back light and contrast on Trane Tracker Version 12?
    • A
      Anne ClarkSep 18, 2025
      If the touch-screen back light and contrast are out of adjustment on your Trane Air Conditioner, perform the adjust brightness and contrast procedure from the display module.

Summary

Chapter 1 Overview

Controller components

Describes the three main components: termination, main, and display modules.

Termination module

Details the housing, termination board, and cable access of the termination module.

Main module

Explains the main module's housing, logic board, and Ethernet board functionality.

Display module

Covers the display module's housing, LCD touch screen, and alarm LED.

Model numbers

Explains how model numbers identify controller information and defines each digit.

Tracker controller specifications

Lists detailed technical specifications for the Tracker controller, including power, environment, and dimensions.

UCM capacities for models 12 and 24

Details the maximum number and types of Unit Control Modules (UCMs) for Tracker models 12 and 24.

UCM capacities for model WSHP

Outlines the maximum number and types of Unit Control Modules (UCMs) for the Tracker model WSHP.

Before installation

Provides essential pre-installation steps including shipment verification, damage inspection, and storage.

Chapter 2 Termination module mounting

Select a location for the controller

Guides selection of a suitable, secure, and accessible indoor location for the controller.

Verify location conformance to specifications

Ensures the chosen location meets the controller's environmental and operational specifications.

Verify location conformance to dimensions and clearances

Confirms adequate space for the controller and necessary ventilation, cable, and service access.

Verify location conformance to optimal viewing angles

Ensures the controller is mounted at a height and location that allows optimal touch screen viewing.

Mount the termination module

Provides instructions for physically attaching the termination module to a wall or conduit box.

Installing electrical conduit

Details the process for installing electrical conduit for wire entry into the termination module.

Chapter 3 Termination board wiring

Wire 24 Vac power

Explains how to connect the 24 Vac power supply to the termination board terminals.

Wire optional inputs and outputs

Covers wiring specifications and procedures for optional inputs and outputs like alarm relay and sensors.

Wire the alarm relay

Provides steps for wiring the alarm relay output to the termination board.

Wire the priority shutdown device

Details the procedure for wiring a priority shutdown device input to the termination board.

Wire the utility pulse meter

Explains how to wire the utility pulse meter input to the termination board.

Wire the thermistor

Provides instructions for wiring the thermistor input for outdoor air temperature sensing.

Wire the UCMs

Covers wiring Unit Control Modules (UCMs) to the Tracker termination board via the Comm5 link.

Termination resistor placement for Comm5 links

Explains the correct placement of 105 Ω termination resistors for Comm5 communication links.

Chapter 4 Main module mounting

Main module mounting

Details the procedure for attaching the main module to the termination module.

Chapter 5 Display module mounting

Display module mounting

Provides instructions for attaching the display module to the main module.

Chapter 6 PC workstation wiring

Verify PC workstation specifications

Instructs to verify that the PC meets minimum software and hardware requirements.

Direct connection to PC workstation

Explains how to establish an EIA-232 direct connection using an RJ-12 cable and adapter.

Modem connection to PC workstation

Details how to connect the controller to a PC workstation using an RJ-11 cable and modem.

Ethernet connection to PC workstation

Guides on establishing an Ethernet LAN connection, including methods over existing LAN, through a hub, or direct.

Chapter 7 Troubleshooting

Troubleshooting components

Introduces troubleshooting tools like LEDs, service pin buttons, and jumpers.

LEDS

Describes the function and status of various LEDs on the controller for troubleshooting.

Service pin buttons and jumper

Explains the purpose of service pin buttons (reset, Neuron ID) and the factory-use jumper.

Symptom;action troubleshooting

Lists common symptoms and provides corresponding actions to resolve Tracker system problems.

Chapter 8 Maintenance

Cleaning the touch screen

Provides methods for cleaning the controller's touch screen using cloths or compressed air.

Calibrating the touch screen

Outlines the step-by-step procedure to calibrate the touch screen for accurate input.

Appendix A Installation checklists

Required supplies

Lists essential supplies required for all Tracker installations.

Optional supplies

Lists supplies that may be necessary depending on the specific Tracker installation.

Comm5 UCM identification and location

Provides a table to record UCM names, locations, and 12-digit identifiers for setup.

Termination module post-installation checklist

A checklist to verify correct wiring of circuits connected to the termination board.

Appendix B Declaration of Conformity

Declaration of Conformity

The official statement declaring the product's compliance with relevant standards and directives.

Trane Tracker Version 12 Specifications