Do you have a question about the Trane TSC060 and is the answer not in the manual?
Model | TSC060 |
---|---|
Compressor Type | Scroll |
Refrigerant | R-410A |
Weight | Varies based on configuration; refer to specific model submittal |
Refrigerant Type | R-410A |
Voltage | 460V |
Cooling Capacity | 60 Tons |
Power Supply | 460/3/60 (Standard), Other options available |
Records revisions and updates made to the manual document.
Provides a summary of the manual's content, purpose, and scope.
Explains how to interpret unit model numbers for identification.
Defines the naming conventions and terms used for unit components.
Details unit nameplates, compressor data, and general unit characteristics.
Highlights safety warnings and cautions for potential hazards.
Describes sensors and inputs that interface with the control system.
Explains various zone sensor modules and related control options.
Covers pre-installation checks, storage, and required unit clearances.
Illustrates minimum operating and service clearances for unit installation.
Provides detailed dimensional data for unit sizing and placement.
Lists weights for units and optional accessories for rigging.
Details requirements for unit foundations and rooftop mounting.
Illustrates air openings and ductwork installation guidelines.
Provides guidelines for connecting ductwork to the unit.
Instructions for verifying and installing the roof curb.
Provides instructions and warnings for safely lifting and moving the unit.
Covers general requirements for unit installation and checks.
Covers economizer position and electric heat limit switch setup.
Details steps for converting the unit to horizontal discharge.
Provides instructions for replacing the TCO-A limit control.
Guides on main power, low voltage wiring, and condensate drain setup.
Covers filter installation and field-installed wiring requirements.
Presents diagrams for thermostats, routing, and optional control wiring.
Explains wiring for averaging multiple space temperature sensors.
Details procedures for checking and correcting voltage imbalance.
Guides on checking and correcting electrical phasing for motors.
Details ReliaTel control diagnostics and component test modes.
Outlines procedures to verify proper system airflow and fan speed.
Guides for starting economizer, compressor, and heating stages.
Lists final checks to perform before leaving the unit after installation.
Describes how to inspect, adjust, and maintain fan belt tension.
Outlines routine checks for filters, coils, and seasonal components.
Provides step-by-step instructions for cleaning evaporator and condenser coils.
Guides on recording unit data and sample maintenance logs.
Explains how to use ReliaTel for unit diagnostics and status checks.
Describes how to check system status and interpret failure indications.
Details tests for zone sensors, filter switches, and fan failure switches.
Covers tests for setpoints, mode selection, LEDs, and RTRM module.
Guides on troubleshooting economizer issues and cooling failures.