Loading...
16Thermostat User Guide
ZWave Install
Z-Wave™ controllers from various manufacturers may support the Z-Wave™ Thermostat General V2 Device class used
by the Trane Z-Wave™ Thermostat. The following procedure will allow the thermostat to be added to a Z-Wave™ network.
Î If you are using a controller that is not a Schlage bridge, consult the instructions that came with the controller
to find out how to enroll a new device.
Inclusion
1. Install a new, high-quality 9-volt battery into the bridge.
2. Hold the bridge within 6 feet (1.8 meters) of the thermostat throughout the entire inclusion process.
Î After you begin the inclusion process, you have 30 seconds to complete the remainder of the steps. Study
the steps below before beginning.
3. Press and release the plus (+) button on the bridge.
4. Press the MENU button on the thermostat.
5. Scroll to ZWave Install. Then press the Select button.
6. Press the Yes button.
7. Observe the lights on the bridge. The orange light will blink while enrollment is taking place. Enrollment is
complete when the orange light becomes solid.
Exclusion
1. Install a new, high-quality 9-volt battery into the bridge.
2. Hold the bridge within 6 feet (1.8 meters) of the thermostat throughout the entire exclusion process.
Î Note: After you begin the enrollment process, you have 30 seconds to complete the remainder of the
steps. Study the steps below before beginning.
3. Press and release the minus (-) button on the bridge.
4. Press the MENU button on the thermostat.
5. Scroll down to Z-Wave Install and press the Select button.
6. Press the Yes button to exclude the thermostat.
7. Observe the lights on the bridge. The orange light will blink while exclusion is taking place. Exclusion is complete
when the orange light becomes solid.
Inclusion and Exclusion
Inclusion or exclusion is started by putting the controller into add node or remove node state and performing the procedure
outlined above. As part of the process, the thermostat sends a node information frame at normal power. Low power
inclusion or low power exclusion is not possible.