- 42 -
Battery charge indication ................ Battery symbol with 4 bars to show percent of full charge
4 bars = 80% - 100%, 3 bars = 60% - 80%, 2 bars = 40% - 60%, 1 bar = 20% - 40%,
flashing battery symbol = 0% - 20%
Relay Output
Relay types ......................................................... Dual relays with single common, solid state
AC rating ............................................... 120 mA @ 350Vac peak, 35 ohms series resistance
DC rating ........................................................ 120 mA @ 350Vdc, 35 ohms series resistance
Isolation to signal common ................................................................................. 5300 Vac rms
Setpoint setup .............................................................................................. Via keypad or PC
Response rate (selectable) ...... 60/second or 50/second (each 1 conversion or 256 samples)
Response filtering (selectable) ................................................................. Filtered or unfiltered
Active modes (selectable) ........... Above or below setpoint, latching or non-latching, disabled
Visual active Alarm Indication........................... AL1 LED (yellow), AL2 LED (red), Go (green)
Audible active alarm indication ................................................................................ Selectable
Activation time delay (selectable) ............................................................ 1 to 128 conversions
Setpoint / lockout modes (selectable) ................................... 1) Display and change setpoints
................................................................................... 2) Display but do not change setpoints
.................................................................................. 3) Neither display nor change setpoints
Serial Interface to PC
Signal type ................................................................................................................. USB 2.0
Baud rates (selectable) .............................. 300, 600, 1200, 2400, 4800, 9600, 19200, 38400
Serial protocol ................................................................. Point-to-point ASCII, PC compatible
Control Inputs
Number of inputs ....................................................................................................... 2 (A & B)
Input activation ................................................................................................ Short to ground
Control input action ............................. Meter Reset, Function Reset, Display Peak or Valley,
Tare, Tare Reset, Log
Mechanical
Dimensions .............................................................. 1.28” x 3.30” x 7.50” (32 x 84 x 185 mm)
Weight ................................................................................................................. 10 oz (280 g)
Case material .............................................................................................. ABS-94HB plastic
Provision for stand ..................................................... 3 inserts, 8-32 UNC threads, 3/8” deep,
1.500” triangle base, 1.750 triangle height (see photo on page 10)
Keypad .............................................................. Membrane type, 8-keys with tactile feedback
Display type ...................................................................................................... Reflective LCD
Displayed info ...... 6 large digits, 5 small digits, charge bargraph, units of measure, indicators
Electrical connectors .......................... DB9 male for TEDS and signal connection to load cell,
3-pin jack plus detachable connector for dual relay outputs
3-pin jack plus detachable connector for control inputs
10 foot (3 m) USB cable to charging unit or computer
Environmental
Operating temperature .......................................................................................... 0°C to 55°C
Storage temperature ......................................................................................... -20°C to 60°C
Relative humidity ....................................................... 95% from 0°C to 40°C, non-condensing
Environmental sealing ...................................................................Dust and humidity resistant

Related product manuals