14
Disable CAN Communication (module):
1. Disconnect power from module.
2. Move dipswitches 4-6 to ON position.
3. Connect CAN-H to GND and CAN-L to +12V.
4. Power up system.
5. LED will light for 5 seconds and go off.
6. Disconnect power from module and CAN-H and CAN-L.
7. Move dipswitches 4-6 back to their original position.
8. Power up module.
Note:
 If the module is powered up while DIP switches 4-6 are ON,
CAN communication is enabled.
 If new FOBs are trained to a CAN-disabled module, the module
must be CAN-disabled again after the FOB train process is
complete.
Disable CAN Communication (keypad):
1. Disconnect power from keypad.
2. Connect yellow wire to GND.
3. Connect CAN-H to GND and CAN-L to +12V.
4. Power up system.
5. Keypad will beep 5 seconds and then provide 5 short beeps.
6. Disconnect power from keypad and CAN-H and CAN-L.
7. Disconnect yellow wire from GND.
8. Power up keypad.